  • Int J Pharm Pharm Sci, Vol 13, Issue 7, 49-58Original Article

    DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF ETHINYL ESTRADIOL AND GESTODENE IN BULK AND PHARMACEUTICAL DOSAGE FORMS

    D. SUCHITRA1, BATTU SATYANARAYANA2*

    1Department of Pharmaceutical Analysis and Quality Assurance, University College of Technology, Osmania University, Hyderabad, Telangana, India, 2Department of Chemistry, University College of Science, Osmania University, Hyderabad, Telangana, India
    *Email: satyambchem@yahoo.co.in

    Received: 26 Mar 2021, Revised and Accepted: 18 May 2021


    ABSTRACT

    Objective: The principal objective of this study is to develop and validate a simple, new, fast, selective, precise, and economic stability-indicating the RP-HPLC method for the simultaneous estimation of Ethinyl estradiol and Gestodene in a bulk and pharmaceutical dosage form.

    Methods: The present method was developed and validated on a Waters HPLC system using Phenomenex Gemini C18(250 mm × 4.6 mm i.d., 5 µm particle size) column and mobile phase composition of phosphate buffer: Acetonitrile (75:25 v/v) and the pH was adjusted to 3.6 using dilute orthophosphoric acid. The system was regulated at 1.0 ml/min flow rate at 237 nm UV detection.

    Results: The two drugs Ethinyl Estradiol and Gestodene, were eluted at 1.788 min and 3.475 min retention time, respectively. The analytical parameters such as accuracy, precision, linearity, LOD, LOQ, ruggedness, and robustness were used for validating the developed method according to International Conference on Harmonisation [ICH] guidelines. Linearity was exhibited over the concentration range of 10-50µg/ml and 25-125µg/ml for Ethinyl Estradiol and Gestodene, respectively. The method revealed the Limit of Detection and Quantitation values for Ethinyl Estradiol and Gestodene were 1.399µg/ml, 3.909µg/ml and 4.24µg/ml, 11.85µg/ml, respectively. The stress testing was carried out to give rise to degradation products by exposing the drugs to acid, alkali, thermal, oxidative, photolytic, and hydrolytic degradation. The obtained data showed that the content of Active pharmaceutical ingredients and the degradation products were successfully separated without any interference, which confirmed the stability-indicating nature of the developed method.

    Conclusion: The new, simple, rapid, selective, precise, and economic stability-indicating RP-HPLC method has been successfully developed and validated. It can be satisfactorily applied for the periodic laboratory quantitative estimation of Ethinyl Estradiol and Gestodene in formulations and active pharmaceutical ingredients.

    Keywords: RP-HPLC, Method development, Method validation, Forced degradation studies


    INTRODUCTION

    Ethinyl Estradiol is chemically (8R,9S, 13S, 14S, 17R)-17-ethynyl-13-methyl-7,8,9,11,12,14,15,16-octahydro-6H-cyclopenta[a] phenanthrene -3,17-diol [fig. 1], an estrogen drug is used widely in birth control pills in combination with progestins. It is used to treat menopausal symptoms, gynecological disorders, and certain hormone-sensitive cancers [1]. Ethinyl estradiol binds to the estrogen receptor complex, enters the nucleus, and activates the DNA transcription process. It prevents ovulation by decreasing luteinizing hormone, which in turn decreases endometrial vascularization and decreases gonadotrophic hormone. In epididymal tissue, it lowers testosterone levels and prevents prostatic cancer by inhibiting the 5-alpha reductase enzyme. Along with cancer treatment, it is also used for osteoporosis [2].

    Fig. 1: Chemical structure of Ethinyl estradiol

    Gestodene is chemically (8R,9S,10R,13S,14S,17R)-13-ethyl-17-ethynyl-17-hydroxy-1,2,6,7,8,9,10,11,12,14-decahydrocyclopenta[a]phenanthene-3-one [fig. 2], a progestogen hormonal contraceptive used in birth control pills and also used in menopausal hormone therapy [3]. It inhibits growth hormone release from the pituitary gland and suppresses ovulation. It also disrupts fertilization and inhibits implantation [4].

    Fig. 2: Chemical structure of gestodene

    Femovan tablet has 0.03 mg of Ethinyl estradiol and 0.075 mg of Gestodene as active pharmaceutical ingredients. This combination drug is used for contraception and in the treatment of irregular periods. This drug helps to prevent the release and fertilization of the egg. It is also used to treat ovarian cancer.

    From the literature survey, it was revealed that several methods like RP-HPLC [5, 6], UPLC/MS-MS [7], and stability-indicating RP-HPLC [8] methods are described for the quantitative determination of Ethinyl estradiol and Gestodene and Ethinyl estradiol and drospirenone [9] in combination form. But the published stability-indicating method’s total analysis time was 65 min which takes more time for analysis and consumes more mobile phase thus becomes expensive. Therefore, it felt necessary to develop and validate a new, rapid, and economic stability-indicating RP-HPLC method, which can be successfully applied for the regular laboratory analysis of Ethinyl estradiol and Gestodene drugs.

    MATERIALS AND METHODS

    Chemicals and reagents

    The standard drugs of Ethinyl estradiol and Gestodene were collected as gift samples from Sura labs, Hyderabad. The commercial tablet dosage form FEMOVAN containing 0.03 mg of Ethinyl estradiol and 0.075 mg of Gestodene, marketed by Bayer Zydus Pharma Ltd., was procured from a local pharmacy. Acetonitrile (HPLC grade), Methanol (HPLC grade), water (HPLC grade), and orthophosphoric acid used for the preparation of the mobile phase were a product of Merck.

    Instrument used

    The present method was quantitatively estimated on a Waters Alliance 2695 separation module HPLC system, and data processing was done using Empower 2 software. The eluates were monitored at 237 nm by 996 Photo-diode array detectors. Sonication’s dissolution and degassing of the solvents and the mobile phase were achieved on Labman digital ultra sonicator. The pH of the solution was adjusted by using a Lab India pH meter.

    Methods

    Chromatographic conditions

    The simultaneous estimation was achieved on Phenomenex Gemini C18(250 mm × 4.6 mm i. d, 5 µm particle size) column with mobile phase composition of phosphate buffer and acetonitrile (75:25 v/v, pH 3.6) adjusted to a flow rate of 1.0 ml/min for a total 8 min run time. The eluates were monitored at 237 nm by a Photo-diode array detector, and the two drugs Ethinyl Estradiol and Gestodene were eluted at 1.788 min and 3.475 min retention time, respectively.

    Preparation of stock and working stock solutions

    An accurately weighed 10 mg of Ethinyl Estradiol and Gestodene standard drugs were dissolved in 10 ml of mobile phase, sonicated, and filtered. Further prepared 20µg/ml and 50µg/ml concentration working stock solutions of Ethinyl Estradiol and Gestodene respectively, mixed thoroughly, sonicated, and filtered through 0.45µ membrane filter. Introduced the samples into the HPLC system, recorded the chromatograms, and noted the best-optimized conditions to proceed for validation as per ICH guidelines.

    Preparation of sample solution

    Femovan tablets (containing 0.03 mg Ethinyl estradiol and 0.075 mg Gestodene) were taken and crushed in a mortar using a pestle. An equivalent amount of 10 mg of tablet powder was weighed and dissolved in the diluent, diluted to volume, mixed thoroughly, sonicated, and filtered. Injected the sample in triplicates and calculated the % assay.

    Method validation

    As per ICH guidelines [10, 11], the parameters checked for method validation are Accuracy, precision, linearity, LOD, LOQ, specificity, and robustness [12-14].

    System suitability

    For evaluating the system suitability, the mixed working standard solution of Ethinyl Estradiol and Gestodene was injected five times into the HPLC system, recorded the chromatograms, measured the areas, and calculated the % RSD for all five injections in HPLC.

    Linearity

    The Linearity of the method was determined by plotting the standard curve in the concentration range of 10-50µg/ml and 25-125µg/ml for Ethinyl Estradiol and Gestodene, respectively. The peak areas were noted by injecting each level into the chromatographic system. Plotted a calibration curve of analyte response versus concentration, and by linear regression analysis, the correlation coefficient was calculated.

    Accuracy

    For evaluating the method’s accuracy, added a pre-analyzed sample solution of 20µg/ml of Ethinyl estradiol and 50µg/ml of Gestodene to a known amount of standard solution of Ethinyl Estradiol (10, 20, and 30µg/ml) and Gestodene (25, 50 and 75µg/ml) respectively. All the solutions were prepared and injected in triplicates. Recorded the chromatograms and measured the peak responses. Calculated the Amount found and Amount added for Ethinyl Estradiol and Gestodene and calculated the individual recovery and mean recovery values.

    Precision

    The developed method’s precision was evaluated by Intra-assay precision and Intermediate Precision.

    Intra-day precision

    The repeatability of the method was determined by introducing the standard solution containing 20µg/ml of Ethinyl Estradiol and 50µg/ml of Gestodene for five replicate injections, noted the areas on the same day under unchanged operating conditions over a short period and calculated the % RSD.

    Intermediate precision

    The intermediate precision of the method was evaluated by injecting the standard solution containing 20µg/ml and 50µg/ml of Ethinyl Estradiol and Gestodene, respectively, for five times. Measured the areas and calculated the %RSD for the five replicate injections on different days under unchanged operating conditions.

    Robustness

    The robustness of the developed method was evaluated by deliberate variations in flow rate and mobile phase organic composition.

    Effect of the slight change in flow rate

    Examined the solution at 0.9 ml/min and 1.1 ml/min rather than 1.0 ml/min, under unchanged operating conditions. 20 µl of the mixed standard solution was injected, recorded the chromatograms, and compared with an optimized chromatogram.

    Effect of the slight change of percent organic mobile phase

    The sample was analyzed by varying the percentage of organic mobile phase composition in the ratio of 70:30, 80:20 instead of 75:25, under identical conditions. Injected into the HPLC, recorded the chromatograms and compared with an optimized chromatogram.

    Detection limit

    The Ethinyl estradiol and Gestodene LOD values were quantitated by using the formula-

    LОD= 3.3×σ/S

    Where,

    σ = Standard deviаtiоn of the intercept S = Slоpe оf the cаlibrаtiоn curve

    Limit of quantitation

    The quаntitаtiоn limit оf аn analyte in the samples was quantified by using the formula-

    LОQ=10×σ/S

    Where,

    σ = Stаndаrd deviаtiоn оf the respоnse S = Slоpe оf the cаlibrаtiоn curve

    Forced degradation studies

    According to the ICH guidelines, stress testing was carried out upon exposure to extreme stress conditions of acid, base, peroxide, thermal, UV, and hydrolytic degradation. Later studied the main peak of the drug for peak purity by calculating the percentage of degraded amount and percentage of the active amount.

    Acid degradation

    Added 1 ml of 2N HCl to 1 ml of Ethinyl estradiol and Gestodene stock solutions and refluxed at 60 °C for 30 min. Later 2N NaOH was added to neutralize the solutions and diluted to volume to obtain 20μg/ml and 50μg/ml solutions, respectively. Cooled the solutions to room temperature and filtered. Injected the sample into the HPLC system and recorded the chromatograms.

    Alkaline degradation

    Added 1 ml of 2N sodium hydroxide to 1 ml of Ethinylestradiol and Gestodene stock solutions, refluxed at 60 °C for 30 min. Later, 1 ml of 2N HCl was added for neutralization and diluted to volume to obtain 20μg/ml and 50μg/ml solutions, respectively. Cooled and then filtered through a 0.45μm membrane filter. Injected into the HPLC system and recorded the chromatograms.

    Oxidation degradation

    Added 1 ml of 20% Hydrogen peroxide to 1 ml of Ethinylestradiol and Gestodene stock solutions and kept for 30 min at 60 °C. Later diluted to volume to obtain 20μg/ml and 50μg/ml solution. Cooled and filtered using 0.45μm membrane filter. Injected the sample into the HPLC system and recorded the chromatograms.

    Dry heat degradation

    1 ml of standard drug solution was kept in an oven for six h at 60 °C later, diluted to final volume to obtain 20μg/ml and 50μg/ml solutions Ethinyl estradiol and Gestodene respectively. Cooled and filtered using 0.45μm membrane filter. Injected into the HPLC system and recorded the chromatograms.

    Photodegradation

    For this study, the stock solutions were exposed to UV light for 1d or 200Watt-hm-2 in a photostability chamber and later diluted to volume to obtain 20μg/ml and 50μg/ml solutions of Ethinyl estradiol and Gestodene, respectively, filtered through a 0.45μm membrane filter. Injected the solutions into the HPLC system and recorded the chromatograms.

    Water degradation studies

    Added 1 ml of distilled water to 1 ml of stock solution of Ethinyl estradiol and Gestodene and kept aside at 60 °C for 30 min. Later, diluted to volume to obtain 20μg/ml and 50μg/ml solutions of Ethinyl estradiol and Gestodene, respectively. Filtered the solutions and injected the mixed standard into the HPLC system, and recorded the chromatograms.

    RESULTS AND DISCUSSION

    Method development

    For developing the present method, various columns like Symmetry and Zodiac columns were tried. But finally, Phenomenex Gemini C18(25×0.46 cm, 5 µm) was confirmed to be optimal since all the parameters are within the acceptance criteria like resolution, peak symmetry, and theoretical plates. Various mobile phases tried were water: methanol, Water: Acetonitrile, Phosphate buffer: Methanol, Phosphate buffer: Acetonitrile by varying proportions and at last, the Phosphate buffer: Acetonitrile (75:25 v/v) and the pH was adjusted to 3.6 using dilute orthophosphoric acid by maintaining the system at 1.0 ml/min flow rate at 237 nm UV detection was finalized as optimal. The optimized chromatogram of Ethinyl estradiol and Gestodene was displayed in fig. 3 and resulted in table 1.

    In comparison to the previously reported methods [5, 8], the retention times of Ethinyl estradiol and Gestodene were observed to be more and required more analysis time for quantification. But the present established method requires lesser analysis time and consumes lesser solvents showing retention times of Ethinyl estradiol and Gestodene at 1.788 min and 3.475 min, which is more advantageous in pharmaceutical industries. This revealed that the developed method could be suitably applied for routine laboratory analysis.

    Method validation

    System suitability

    All the efficiency parameters like theoretical plates were observed to be more than 7000 for Ethinyl estradiol and Gestodene drugs. The peak tailing was not more than 2.0. The %RSD for the five replicate injections was not more than 2.0 and ensured that the entire testing system and chemicals used could generate an accurate and precise result by showing all the efficiency parameters within the specified limits. Reported the results in Tables 2 and 3.

    Linearity

    The proposed method was confirmed to be linear in the concentration range of 10-50µg/ml and 25-125µg/ml for Ethinyl Estradiol and Gestodene, respectively, showing a correlation coefficient of 0.999, which was analyzed by linear regression analysis. The results proved that the analyte response is proportional to the analyte concentration in the selected concentration range. The calibration graphs of Ethinyl Estradiol and Gestodene are depicted in fig. 4 and fig. 5 and data in Tables 4 and 5, respectively.

    Accuracy

    The mean recovery values obtained at 50%, 100%, and 150% levels are 99.84% and 99.92% for Ethinyl estradiol and Gestodene, respectively, which are within the acceptance criteria. Thus, it confirmed the method’s accuracy and reported the results in Tables 6 and 7.

    Precision

    The obtained %Relative standard deviation of intra-day precision and intermediate precision of Ethinyl estradiol and Gestodene was found to be not more than 2.0, which is within the acceptance criteria, indicating that the developed method is precise. Reported the measured results of intra-day precision in Tables 8,9 and intermediate precision in Tables 10, 11, 12, and 13.

    Robustness

    The results revealed that the method is robust upon slight changes in flow rate conditions and even by the ±5% organic phase for Ethinyl estradiol. For Gestodene, upon decreasing the %organic phase, the retention time was more, and retention time was less for more %organic phase. There was no significant change in resolution, asymmetry, and plate count. Reported observed results in Tables 14 and 15.

    Limit of detection and limit of quantitation

    Calculated the LOD and LOQ using the standard deviation of intercepts and slope of the calibration curve. The measured detection limit and quantitation limit was found to be 1.399µg/ml and 4.242µg/ml for Ethinyl estradiol and 3.909µg/ml and 11.848µg/ml for Gestodene, respectively. Thus, the present method is confirmed to be highly sensitive.

    Assay determination of ethinyl estradiol and gestodene

    The %Assay of Ethinyl estradiol and Gestodene in Femovan tablets is 100.6% and 98.63%, respectively, and are within the specified limits, which confirmed that the developed method could be successfully applied for the assay of pharmaceutical dosage forms, and reported the results in Tables 16, 17, 18, and 19.

    Degradation studies

    Upon degradation study, observed that Ethinyl estradiol and Gestodene had undergone degradation under all stress conditions. The calculated % degraded amount was within the acceptance criteria. It was observed that the drug was more susceptible to photolysis showing the highest degradation. The successful separation of the obtained degradation products from the active pharmaceutical ingredients without any interference confirmed the specificity. Thus, it proved the stable nature of the developed method. Presented the acidic, basic, oxidative, thermal, photolytic, and hydrolytic degradation chromatograms in fig. 6, 7, 8, 9, 10, and 11, respectively. Reported the calculated results for Ethinyl estradiol and Gestodene in tables 20 and 21, respectively.

    All the method validation parameters are within the acceptance criteria and assured sufficient precision and accuracy. A good linear relationship was observed in the concentration range of 10-50µg/ml and 25-125µg/ml for Ethinyl estradiol and Gestodene, respectively. The detection limit for Ethinyl estradiol was found to be 1.399µg/ml indicating the high sensitivity of the developed method compared to the reported method [6]. The recovery of the analyte was also found to be more than the reported methods [5, 8], indicating a high degree of accuracy. The non-interference of the degraded products with the active pharmaceutical ingredients revealed the stability-indicating nature of the developed method.

    Fig. 3: Optimized chromatogram of ethinyl estradiol and gestodene

    Table 1: Optimized chrоmаtоgrаm result

    S. Nо. Drug Retention time (min) Аreа of the peak Height of the Peak Resolution Peak asymmetry

    No. of theoretical

    plates

    1 Ethinylestradiol 1.788 558647 7658 1.26 7854
    2 Gestodene 3.475 7986585 48546 7.12 1.35 8865

    Table 2: System suitability data of Ethinyl estradiol

    Drug S. Nо. Retention time (min) Analyte response Theoretical plates(N) Peak asymmetry
    Ethinyl estradiol 1 1.788 558748 7854 1.26
    2 1.792 556985 7845 1.29
    3 1.793 557849 7896 1.28
    4 1.794 559865 7824 1.29
    5 1.791 558498 7869 1.27
    *Mean (n=5) 558389
    ±SD (n=5) 1070.298
    % RSD (n=5) 0.191676

    *Mean of five determinations, SD: Standard Deviation, RSD: Relative Standard Deviation

    Table 3: System suitability data of gestodene

    Drug S. No. Retention time (min) Area of the peak No. of theoretical plates Peak asymmetry Resolution
    Gestodene 1 3.438 7986952 8856 1.36 7.13
    2 3.446 7958484 8874 1.32 7.14
    3 3.444 7986958 8896 1.39 7.15
    4 3.440 7984874 8874 1.34 7.16
    5 3.442 7986989 8859 1.38 7.15
    *Mean (n=5) 7980851
    ±SD (n=5) 12536.55
    % RSD (n=5) 0.157083

    *Mean of five determinations, SD: Standard Deviation, RSD: Relative Standard Deviation

    Table 4: Lineаrity data of ethinylestradiol

    Cоncentrаtiоn µg/ml Аverаge peаk Аreа
    10 253898
    20 501647
    30 751256
    40 985789
    50 1235898

    Fig. 4: Linearity plot of Ethinyl estradiol

    Table 5: Lineаrity data of gestodene

    Cоncentrаtiоn µg/ml Аverаge peаk аreа
    25 3252897
    50 6316585
    75 9438787
    100 12387436
    125 15365874

    Fig. 5: Linearity plot of gestodene

    Table 6: Ethinyl estradiol accuracy data

    Drug Spiking level Peak area

    *Average

    area (n=3)

    Amount added (µg/ml)

    Amount obtained

    (µg/ml)

    *Percentage

    recovery

    Average recovery

    (n=9)

    Ethinyl estradiol 50% 253848 253526 10 9.89 98.9% 99.84%
    252856
    253874
    100% 501563 501858.67 20 20.04 100.2%
    501689
    502324
    150% 748584 748983 30 30.13 100.43%
    749897
    748468

    *Mean of three determinations

    Table 7: Gestodene accuracy data

    Drug

    Spiking

    level

    Peak area

    *Average

    area (n=3)

    Amount added

    (µg/ml)

    Amount found

    (µg/ml)

    *Percentage recovery

    (n=3)

    Average recovery

    (n=9)

    Gestodene 50% 3314535 3315176.67 25 25.183 100.7% 99.92%
    3312453
    3318542
    100% 6287487 6284538.67 50 49.68 99.37%
    6279654
    6286475
    150% 9328748 9323285 75 74.76 99.68%
    9315462
    9325645

    *Mean of three determinations

    Table 8: Repeatability data of Ethinyl estradiol

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Ethinyl estradiol 1 1.789 558748 7896 1.26
    2 1.780 558698 7845 1.28
    3 1.790 558475 7892 1.29
    4 1.791 558698 7849 1.27
    5 1.792 558265 7829 1.28
    *Mean (n=5) 558576.8
    ±SD (n=5) 203.8816
    %RSD (n=5) 0.0365

    *Mean of five determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 9: Repeatability data of gestodene

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Gestodene 1 3.408 7986985 8856 1.36
    2 3.414 7985487 8849 1.37
    3 3.419 7985468 8874 1.39
    4 3.428 7968547 8957 1.38
    5 3.435 7982564 8965 1.37
    *Meаn (n=5) 7981810
    ±SD (n=5) 7585.473
    %RSD (n=5) 0.095034

    *Mean of five determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 10: Day 1 Intermediate precision data of ethinylestradiol

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Ethinyl estradiol 1 1.792 558965 7859 1.29
    2 1.789 558476 7895 1.28
    3 1.787 558947 7829 1.27
    *Mean (n=3) 558796
    ±SD (n=3) 277.2742
    %RSD (n=3) 0.04962

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 11: Day 1 Intermediate precision data of gestodene

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Gestodene 1 3.435 7986986 8849 1.38
    2 3.477 7985985 8879 1.37
    3 3.482 7898654 8896 1.39
    *Mean (n=3) 7957208
    ±SD (n=3) 50712.01
    %RSD(n=3) 0.637309

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 12: Day 2 Intermediate precision data of ethinyl estradiol

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Ethinyl estradiol 1 1.793 568965 7989 1.28
    2 1.789 569854 7986 1.29
    3 1.790 569878 7994 1.28
    *Mean (n=3) 569565.7
    ±SD (n=3) 520.331
    %RSD (n=3) 0.091356

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 13: Day 2 Intermediate precision data of gestodene

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Gestodene 1 3.478 8045652 8987 1.38
    2 3.473 8065879 8959 1.39
    3 3.474 8075847 8937 1.37
    *Mean (n=3) 8062459
    ±SD (n=3) 15385.22
    %RSD 0.190825

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 14: Robustness data of ethinyl estradiol

    Slightly changed parameters Peak аreа Retention time (min) No. of theoretical plates Peak asymmetry

    Flow rate

    (ml/min)

    1.0 558647 1.788 7854
    0.9 636589 1.867 7978
    1.1 Mоre flоw rаte оf 0.9 ml/min 535685 1.744 7576
    % of Acetonitrile 20 548576 1.831 7367
    30 525874 1.874 7296

    Table 15: Robustness study data of gestodene

    Slightly changed parameters Peak area Retention time (min) No. of theoretical plates Peak asymmetry

    Flow rate

    (ml/min)

    1.0 7986585 3.475 8865
    0.9 8265847 3.724 9152
    1.1 7658745 3.097 8685
    % Acetonitrile 20 7758498 6.242 8475
    30 7659854 2.402 8369

    Table 16: Assay data оf Ethinyl estradiol standard

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Standard Ethinyl estradiol 1 1.791 558698 7854 1.26
    2 1.794 558674 7822 1.28
    3 1.793 558694 7895 1.29
    4 1.792 558748 7826 1.27
    5 1.788 558962 7849 1.26
    *Mean (n=5)0 558755.2
    ±SD (n=5) 118.7737
    %RSD (n=5) 0.021257

    *Mean of five determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 17: Assay data of gestodene standard

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry Resolution
    Gestodene standard 1 3.442 7986852 8857 1.36 7.15
    2 3.440 7985685 8874 1.34 7.14
    3 3.444 7984573 8892 1.35 7.16
    4 3.446 7986365 8849 1.39 7.15
    5 3.438 7989856 8825 1.35 7.18
    *Meаn (n=5) 7986666
    ±SD (n=5) 1977.644
    %RSD (n=5) 0.024762

    *Mean of five determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 18: Аssаy data of ethinyl estradiol sample

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Ethinyl estradiol Sample 1 1.791 562453 7965 1.28
    2 1.791 563124 7982 1.29
    3 1.794 563256 7985 1.29
    *Mean (n=3) 562944.33
    ±SD (n=3) 430.59
    %RSD (n=3) 0.076

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Table 19: Аssаy data of gestodene sample

    Drug Injection Retention time (min) Peak area No. of theoretical plates Peak asymmetry
    Gestodene sample 1 3.434 8012432 7264 1.39
    2 3.442 8023654 7285 1.38
    3 3.440 8012543 7293 1.37
    *Mean (n=3) 8016209.67
    ±SD (n=3) 6447.22
    %RSD (n=3) 0.08

    *Mean of three determinations, SD: Standard Deviation, %RSD: Relative Standard Deviation

    Fig. 6: Ethinylestradiol and Gestodene acidic degradation chromatogram

    Fig. 7: Ethinyl estradiol and gestodene alkaline degradation chromatogram

    Fig. 8: Ethinyl estradiol and gestodene oxidative degradation chromatogram

    Fig. 9: Ethinylestradiol and gestodene thermal degradation chromatogram

    Fig. 10: Ethinyl estradiol and gestodene photolytic degradation chromatogram

    Fig. 11: Ethinyl estradiol and gestodene hydrolytic degradation chromatogram

    Table 20: Forced degradation studies data for Ethinyl estradiol

    S. No. Stress condition Peak area % of degraded amount % of active amount Total % of amount
    1 Standard 558647 0 100% 100%
    2 Acidic 476693.48 14.67 85.33 100%
    3 Basic 515351.85 7.75 92.25 100%
    4 Oxidative 497307.55 10.98 89.02 100%
    5 Thermal 486413.94 12.93 87.07 100%
    6 Photolytic 395186.88 29.74 70.74 100%
    7 Water 491832.81 11.96 88.04 100%

    Table 21: Forced degradation studies data for gestodene

    S. No. Stress condition Peak area % of degraded amount % of active amount Total % of amount
    1 Standard 7986585 0 100% 100%
    2 Acidic 6733489.81 15.69 84.31 100%
    3 Basic 7271785.64 8.95 91.05 100%
    4 Oxidative 7032188.09 11.05 88.05 100%
    5 Thermal 6880442.98 13.85 86.15 100%
    6 Photolytic 5154541.96 35.46 64.54 100%
    7 Hydrolysis 7108859.31 10.99 89.01 100%

    CONCLUSION

    The established present method revealed that it is simple, selective, specific, and can generate accurate and precise results. Moreover, the shorter duration of analysis time and lesser mobile phase consumption confirmed that the method is rapid and economical. The successful separation of the forced degradation products from the active pharmaceutical ingredients without any interference confirmed the stability-indicating nature of the developed method. Hereupon, the present method can be satisfactorily applied for the routine laboratory simultaneous estimation of Ethinyl estradiol and Gestodene.

    ACKNOWLEDGEMENT

    We are grateful to Sura Labs, Hyderabad, for supplying the Ethinyl estradiol and Gestodene standard drugs as gift samples to carry out the research work.

    FUNDING

    Nil

    AUTHORS CONTRIBUTIONS

    We declare that the author’s present work was done and is an original work. D. Suchitra has carried out the research work. Professor Battu Satyanarayana guided, proofread the manuscript, suggested the necessary corrections, and helped in writing the manuscript.

    CONFLICT OF INTERESTS

    Declared none

    REFERENCES

    1. https://en.m.wikipedia.org/wiki/Ethinylestradiol [Last accessed on 10 Feb 2021]

    2. https://pubchem.ncbi.nlm.nih.gov/compound/Ethinylestradiol [Last accessed on 10 Feb 2021]

    3. https://en.m.wikipedia.org/wiki/Gestodene [Last accessed on 10 Feb 2021].

    4. https://pubchem.ncbi.nlm.nih.gov/compound/Gestodene [Last accessed on 10 Feb 2021]

    5. Kanchan Nautiyal, Ramakrishna K. Analytical method development and validation for simultaneous determination and quantification of ethinyl estradiol and gestodene in combined tablet dosage form by RP-HPLC. J Chem Pharm Sci 2014;6:74-80.

    6. Aleksandra Laban, Slavko Markovic, Milena Stankov, Predrag Djurdjevic. Simultaneous determination of gestodene and ethinyl estradiol in contraceptive formulations by RP-HPLC. Anal Lett 2004;37:273-82.

    7. Xiong Z, Sun X, Huo T, Li N, Zheng Y, Sun Y. Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma. Biomed Chromatogr 2010;24:160-8.

    8. Kishore Kumar I, Jayaprakash P, Sivannarayana Reddy V, Sriramulu J. A stability-indicating high-performance liquid chromatographic method for separation and quantification of impurities in ethinylestradiol and gestodene tablets. J Pharm Biol 2017;7:33-40.

    9. Praveen C, Ranganath MK, Divakar P. Method development and validation for simultaneous estimation of ethinyl estradiol and drospirenone and forced degradation behavior by HPLC in the combined dosage form. Pharm Anal Acta 2013;4:1-5.

    10. ICH, Q2B-Validation of Analytical procedures; Methodology, International Conference on Harmonization; 1996.

    11. International Conference on Harmonization, ICH Q1 A [R2]; Stability Testing of New Drug substances and products; 2003.

    12. Snyder LR, Kirkland JJ, Glajch JL. Practical HPLC method development. 2nd ed. Hoboken: John Wiley and Sons, Inc; 1997.

    13. Vikas Kumar Pal, Yogendra Pal. Analytical method development and method validation for determination assay and content uniformity of levonorgestrel by reversed-phase high-performance liquid chromatography. Asian J Pharm Clin Res 2020;13:101-7.

    14. Majan Naim, Aejaz Ahmed, Khan GJ. Stability indicating reverse-phase High-Performance liquid chromatography method development and validation for simultaneous estimation of Telmisartan and Benidipine hydrochloride in the pharmaceutical dosage form. Asian J Pharm Clin Res 2018;11:342-50.