EXPERIMENTAL STUDY ON IN-POND HEAT EXCHANGER PROVIDED WITH TWISTED TAPES

Authors

  • Karunamurthy K School of Mechanical and Building Sciences, VIT University, Chennai, Tamil Nadu, India
  • Nayan Singh Department of, Politecnico Di Milano, Milan, Italy.
  • Vivek Singh Department of CSE VIT University, Chennai, Tamil Nadu, India. Email

DOI:

https://doi.org/10.22159/ajpcr.2017.v10s1.20515

Keywords:

In-Pond Heat Exchanger, Heat Transfer Augmentation, Twisted Tapes, Twist Ratio

Abstract

In-pond heat exchangers (IHE) are used in salinity gradient solar ponds (SGSP), to transfer heat from hot saline water of the lower convective zone to the heat transfer medium. The performance of the SGSP depends on the performance of the IHE, which in turn depends on the method of heat transfer augmentation. A laboratory model IHE was fabricated to augment the heat transfer using helical twisted tapes (HTTs). The effects of varying twist ratio and double TTs on pressure drop and heat transfer were studied in this experimental work. Conventional HTTs of three twist ratios (Y=7, 9, 11), twin TTs of co-swirl flow (CoTT), and counter-swirl TTs (CTT) with Y=7 were provided in the flow path of the heat exchanger tube for analysis. From the results, it is observed that TTs with less twist ratio yielded higher rate of heat transfer by sacrificing the pressure drop. Compared to single TT, double TT provided better thermal performance. The pressure drop and rate of heat transfer for CTT are more compared to all other cases, including double TT with co-swirl flow.

Downloads

Download data is not yet available.

References

Webb RL. Principles of Enhanced Heat Transfer. New York USA: Taylor & Francis; 1994.

Murugesan P, Mayilsamy K, Suresh S, Srinivasan PS. Heat transfer and pressure drop characteristics in a circular tube fitted with and without V-cut twisted tape insert. Int Commun Heat Mass Transf 2011;38(3):329-34.

Karunamurthy K, Murugumohankumar K, Suresh S. Performance analysis of an in_pond heat exchanger of a salt gradient solar pond. Appl Solar Energy 2014;50(2):84-9.

Hasanpour A, Farhadi M, Sedighi K. Experimental heat transfer and pressure drop study on typical, perforated, V-cut and U-cut twisted tapes in a helically corrugated heat exchanger. Int Commun Heat Mass Transf 2016;71:126-36.

Karunamurthy K, Murugumohankumar K, Suresh S. Enhancement of heat transfer in pilot simulated solar ponds using modified tube inserts. Euro J Sci Res 2012;91(1):165-73.

Tamna S, Kaewkohkiat Y, Skullong S, Promvonge P. Heat transfer enhancement in tubular heat exchanger with double V-ribbed twisted-tapes. Case Stud Thermal Eng 2016;7:14-24.

Dizaji HS, Jafarmadar S, Mobadersani F. Experimental studies on heat transfer and pressure drop characteristics for new arrangements of corrugated tubes in a double pipe heat exchanger. Int J Therm Sci 2015;96:211-20.

Wenbin T, Yong T, Boa Z, Longsheng L. Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube with small pipe inserts. Int Commun Heat Mass Transf 2014;56:1-7.

Saha SK, Dutta A, Dhal SK. Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted tape elements. Int J Heat Mass Trans 2001;44(22):4211-23.

Webb RL, Kim NH. Principles of Enhanced Heat Transfer. 2nd ed. New York: Taylor and Francis; 2005.

Dewan A, Mahanta P, Raju KS. Review of passive heat transfer augmentation techniques. Proc Inst Mech Eng Part A J Power Energy 2004;218:509-27. 12. Eiamsa-ard S, Wongchareeb K, Eiamsa-ard P, Thianpong C. Thermohydraulic investigation of turbulent flow through a round tube equipped with twisted tapes consisting of centre wings and alternate-axes. Exp Thermal Fluid Sci 2010;34(8):1151-61.

Saravanan A, Senthilkumar JS, Jaisankar S. Performance assessment in V-trough solar water heater fitted with square and V-cut twisted tape inserts. Appl Thermal Eng 2016;102:476-86.

Prasada PV, Gupta AV, Sreeramulu M, Sundar LS, Singh MK, Sousa AC. Experimental study of heat transfer and friction factor of Al2O3 nanofluid in U-tube heat exchanger with helical tape inserts. Exp Thermal Fluid Sci 2015;62:141-50.

Kothandaraman CP, Subrahmanyan S. Heat and Mass Transfer Data Book. New Delhi: New Age International Publishers; 2014.

Manglik RM, Bergles AE. Heat transfer and pressure drop correlations for twisted-tape inserts in isothermal tubes: Part I - laminar flows. J Heat Trans 1993;115(4):881-9.

Abdolbaqi MK, Azmi WH, Mamat R, Mohamed NM, Najafi G. Experimental investigation of turbulent heat transfer by counter and co-swirling flow in a flat tube fitted with twin twisted tapes. Int Commun Heat Mass Trans 2016;75:295-302.

Sivashanmugam P, Suresh S. Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube fitted with helical screw-tape inserts. Chem Eng Process 2007;46(12):1292-8.

Published

01-04-2017

How to Cite

K, K., N. Singh, and V. Singh. “EXPERIMENTAL STUDY ON IN-POND HEAT EXCHANGER PROVIDED WITH TWISTED TAPES”. Asian Journal of Pharmaceutical and Clinical Research, vol. 10, no. 13, Apr. 2017, pp. 467-70, doi:10.22159/ajpcr.2017.v10s1.20515.

Issue

Section

Original Article(s)