A SIMULTANEOUS ESTIMATION, VALIDATION AND FORCED DEGRADATION STUDIES OF 5-FLUOROURACIL AND TEGAFUR IN A PHARMACEUTICAL DOSAGE FORM USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD

Authors

  • Vaishali Mistry Department of Quality Assurance, Oriental College of Pharmacy, Navi Mumbai, Maharashtra, India.
  • Akshay Yelwe Department of Quality Assurance, Oriental College of Pharmacy, Navi Mumbai, Maharashtra, India.
  • Amey Deshpande Department of Quality Assurance, Oriental College of Pharmacy, Navi Mumbai, Maharashtra, India.

DOI:

https://doi.org/10.22159/ajpcr.2018.v11i12.27858

Keywords:

5-Fluorouracil, Tegafur, Reversed-phase high-performance liquid chromatography, Degradation and validation

Abstract

Objective: The present study describes the stability indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of 5-fluorouracil and tegafur in pharmaceutical dosage forms.

Method: 5-fluorouracil and tegafur the propose RP-HPLC method were developed by using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic separation was carried on shim-pack gist c18 (250 × 4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 50:50% v/v and elements were scanned using a UV detector at 271 nm.

Result: The retention time of 5-fluorouracil and tegafur was found to be 2.74 and 3.66 min, respectively. A linearity response was observed in the concentration range of 13.4 μg/ml–31.3 μg/ml for 5-fluorouracil and 6 μg/ml–14 μg/ml for tegafur, respectively. Limit of detection and limit of quantification of 5-fluorouracil were 10.97 μg/ml and 33.26 μg/ml and for tegafur are 4.89 μg/ml and 14.83 μg/ml, respectively.

Conclusion: The stability indicating that the method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.

Downloads

Download data is not yet available.

Author Biography

Vaishali Mistry, Department of Quality Assurance, Oriental College of Pharmacy, Navi Mumbai, Maharashtra, India.

Quality Assurance Department,

Assistant Professor

References

Garg MB, Sevester JC, Sakoff JA, Ackland SP. Simple liquid chromatographic method for the determination of uracil and dihydrouracil plasma levels: A potential pretreatment predictor of 5-fluorouracil toxicity. J Chromatogr B Analyt Technol Biomed Life Sci 2002;774:223-30.

Friedman MA, Ignoffo RJ. A review of the united states clinical experience of the fluoropyrimidine, ftorafur (NSC-148958). Cancer Treat Rev 1980;7:205-13.

Benvenuto JA, Lu K, Hall SW, Benjaman RS, Loo TL. Disposition and metabolism of 1-(Tetrahydro-2-Furanyl)5-Fluorouracil (Ftorafur) in humans. Cancer res 1978;38:3867-70.

Chu D, Gu J, Liu W, Paul Fawcett J, Dong Q. Sensitive liquid chromatographic assay for the simultaneous determination of 5-fluorouracil and its prodrug, tegafur, in beagle dog plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2003;795:377-82.

ICH Harmonised Tripartite Guideline Validation Of Analytical Procedures Q2(R1) 4 Version Parent Guideline, Dated; 1994.

Moinuddin M, Rahaman SA. Development and validation of RP-HPLC for simultaneous estimation of rosuvastatin calcium and fenofibrate in tablet dosage form. Int J Pharm Pharm Sci 2012;4:150-4.

Patil R, Deshmukh T, Patil V. Stability indicating HPLC method for dapoxetinehcl in bulk and in formulation. Int J Pharm Pharm Sci 2014;6:687-90.

Published

07-12-2018

How to Cite

Mistry, V., A. Yelwe, and A. Deshpande. “A SIMULTANEOUS ESTIMATION, VALIDATION AND FORCED DEGRADATION STUDIES OF 5-FLUOROURACIL AND TEGAFUR IN A PHARMACEUTICAL DOSAGE FORM USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD”. Asian Journal of Pharmaceutical and Clinical Research, vol. 11, no. 12, Dec. 2018, pp. 132-7, doi:10.22159/ajpcr.2018.v11i12.27858.

Issue

Section

Original Article(s)