Objective: A combination of hydrocortisone and tetracycline as topical ophthalmic ointment is used for skin irritations, eye infections, inflammation, skin infections, acne, and rashes. The objective of the current work is to a simple, rapid, accurate, and precise, stability-indicating reverse-phase liquid chromatographic method was developed for the simultaneous estimation of hydrocortisone and tetracycline in bulk and pharmaceutical dosage form.
Methods: The separation was carried out in Discovery C18 column (250 × 4.6 mm, 5 μm) using mobile phase ratio of water (pH 2.2 adjusted with orthophosphoric acid):acetonitrile (40:60 v/v) in an isocratic elution mode with a flow rate of 1.0 ml/min at detection wavelength of 244 nm. The injection volume was 10 μl and the column temperature was set at 30°C.
Results: The retention time for hydrocortisone and tetracycline was found to be 2.214 ± 0.001 min and 3.497 ± 0.001 min, respectively. Calibration curves were linear (r2=0.999) at a concentration range of 2.5–15 mg/ml for both hydrocortisone and tetracycline. The percentage recoveries were found to be 99.13–99.67% for hydrocortisone and 99.39–99.61% for tetracycline. Relative standard deviation was found to be 0.3% for both the drugs. Limit of detection and limit of quantification values of hydrocortisone and tetracycline were found to be 0.09 μg/ml and 0.27 μg/ml and 0.17 μg/ml and 0.52 μg/ml, respectively. The drugs were subjected to various stress conditions and found no interference of degraded products peak at the retention times of analyte peaks.
Conclusion: A rapid and accurate reverse-phase high-performance liquid chromatographic method was developed for simultaneous estimation of hydrocortisone and tetracycline, and the method was validated as per the International Council for Harmonization guidelines. Hence, the developed method can be successfully applied for the simultaneous estimation of hydrocortisone and tetracycline in bulk and ointment formulation.
Downloads
References
Niranjana ES, Sambath Kumar R, Sudha M, Venkateswaramurthy N. Review on clinically developing antibiotics. Int J App Pharm 2018;10:13-8.
Nasir A, Muhammad S, Amjad H, Muhammad I, Muhammad A, Fawad RM, et al. Development and validation of a spectroscopic method for the simultaneous analysis of miconazole nitrate and hydrocortisone acetate in pharmaceutical dosage form. Trop J Pharm Res 2017;16:413-20.
Harika M, Kumar GS. Simultaneous UV-spectrophotometric estimation of hydrocortisone acetate and sulphacetamide sodium in combined dosage form. Int J Pharm Sci Res 2013;4:1901-4.
Ofori-Kwakye K, Adi-Dako O, Bekoe SO, Appiah E, Peprah P. Novel HPLC analysis of hydrocortisone in conventional and controlled release pharmaceutical preparation. J Pharm 2017;2017:1-8.
Rani NU, Rao JV. RP-HPLC determination of hydrocortisone in parenterals. Asian J Chem 2011;23:1407-8.
Sudhakar P, Pankaj S, Birendra S. Validation of stability indicating HPLC method for assay of fusidic acid, hydrocortisone acetate and potassium sorbate in topical pharmaceutical formulation. World J Pharm Pharm Sci 2016;5:1923-38.
Suryakant B, Rajput SJ. RP-HPLC method for simultaneous estimation of hydrocortisone acetate and miconazole nitrate in a cream formulation. Invent J 2014;3:1-4.
Nassar AE, Varshney N, Getek T, Cheng L. Quantitative analysis of hydrocortisone in human urine using a high-performance liquid chromatographic-tandem mass spectrometric-atmospheric-pressure chemical ionization method. J Chromatogr Sci 2001;39:59-64.
Genete G, Hymete A, Adnan AB. Development and validation of HPTLC assay method for simultaneous quantification of hydrocortisone and clotrimazole in cream and applying for stability indicating test. J Chil Chem Soc 2012;57:1199-203.
Emadhussien M. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph. Biomed Chromatogr 2014;52:239-44.
Charoenraks T, Chuanuwatanakul S, Honda K, Yamaguchi Y, Chailapakul O. Analysis of tetracycline antibiotics using HPLC with pulsed amperometric detection. Anal Sci 2005;21:241-5.
ICH Harmonised Tripartite Guideline. Validation of Analytical Procedures: Text and Methodology Q2 (R1), International Conference on Harmonization; 2005.
Published
How to Cite
Issue
Section
The publication is licensed under CC By and is open access. Copyright is with author and allowed to retain publishing rights without restrictions.