VALIDATION OF ASSAY PROCEDURES OF AFOBAZOLEIN MICROCAPSULES

Authors

  • Polkovnikova Yulia Aleksandrovna Department of Pharmaceutical chemistry and pharmaceutical technology, faculty of Pharmacy, Voronezh state university, 394006, Voronezh, street, Studentcheskaya, 3
  • Slivkin Aleksei Ivanovich Department of Pharmaceutical chemistry and pharmaceutical technology, faculty of Pharmacy, Voronezh state university, 394006, Voronezh, street, Studentcheskaya, 3
  • Halahakoon Amila Jeewantha Department of Pharmaceutical chemistry and pharmaceutical technology, faculty of Pharmacy, Voronezh state university, 394006, Voronezh, street, Studentcheskaya, 3

DOI:

https://doi.org/10.22159/ijpps.2017v9i5.16684

Keywords:

Afobazole, HPLC, Microcapsules, Validation

Abstract

Objective: The aim of this work was focused on a simple, rapid, accurate and sensitive method for quantitative analysis of afobazole in microcapsules (afb-m) using high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection.

Methods: The analytical procedure was based on the fractionation characteristics of the afobazole in the chromatography column. The chromatography parameters «Zorbax extend-C18» column (150×2.1 mm i.d. 5 µm particle size), at 40 °C. The isocratic mobile phase was 5.0 M ammonium phosphate buffer (pH 7.0): acetonitrile (30:70; v/v) at a flow rate of at 1.0 ml. min-1. The determinations were performed using UV-Vis detector set at 220 nm.

Results: An assay procedure for afb-m has been validated from indices, such as specificity, correctness, precision, and linearity. The registered retention time of the afobazole stock solution and the sample solution was 1.5 min. The determined accuracy of the method was in the range of 99.67%-100.67%. The analytical curve was linear (r2-0.9996) over a wide concentration range (50%-150%). The method showed sufficient precision, with a relative standard deviation (RSD) smaller than 2%.

Conclusion: The HPLC method developed in this study showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantification of afb-m. The developed assay procedure of afb-m was meeting all the requirements of ICH validation criteria and can be applied for standardisation drug form afb-m.

Downloads

Download data is not yet available.

References

Seredenin SB, Voronin MV. Neuroreceptor mechanisms of action of afobazole. Russian J Exp Clin Pharmacol 2009;72:3-11.

Herrero EP, Del Valle, Martın EM, Galan MA. Development of a new technology for the production of microcapsules based in atomization processes. Chem Eng J 2006;117:137–42.

Sardushkin MV, Hodkova YuV, Kienskaja KI, Avramenko GV. To study the efficiency of microencapsulation and release kinetics of rifampicin from the microcapsules with polylacticacid shell. Chem Eng J 2010;4:233-8.

Senuma Y, Lowe C, Zweifel Y, Hilborn JG, Marison I. Alginate hydrogel microspheres and microcapsules prepared by spinning disk atomization. Biotechnol Bioeng 2000;67:616–22.

Shwinger C, Klemenz A, Busse K, Kressler J. Encapsulation of living cells with polymeric systems. Macromol Symp 2004;210:493–9.

Suchitra Panigrahi, Rajashree Hirlekar. A new stability-indicating RP-HPLC method for determination of curcumin: an application to nanoparticulate formulation. Int J Pharm Pharm Sci 2016;12:102-7.

Sunitha S, Amareshwar P, Santhosh M. A study on the effect of different cellulose polymers on release rate from Tramadol loaded microspheres prepared by an emulsion solvent evaporation method. Asian J Pharm Clin Res 2010;3:35-9.

Hamsika M, Gowda DV, Jigyasa Vindru, Afrasim Moin. Nanotechnology for ophthalmic preparations. Int J Curr Pharm Res 2016;8:5-11.

Marilene Estanqueiro, Maria Helena Amaral, Jaime Conceição, José Manuel, Sousa Lobo. Evolution of liposomal carriers intended to anticancer drug delivery: an overview. Int J Curr Pharm Res 2015;7:26-33.

ICH harmonized tripartite guidelines Q2A Text on validation of analytical procedures, ICH, Geneva; 1995.