ESTIMATION OF CELECOXIB IN HUMAN PLASMA BY RAPID AND SELECTIVE LC-MS/MS METHOD FOR A BIOEQUIVALENCE STUDY
DOI:
https://doi.org/10.22159/ijpps.2018v10i10.28289Keywords:
Celecoxib, LC-MSMS, Solid-phase extraction, Human plasma, Bioequivalence study, Incurred sample reanalysisAbstract
Objective: A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been developed for the determination of celecoxib (CXB) in negative ionization mode.
Methods: Celecoxib and celecoxib-D7 (CXB-D7) as internal standard (IS) were extracted from 300 µl human plasma by solid-phase extraction using strata-X SPE cartridges. Chromatographic separation was achieved on ACE C8-300 (50 × 4.0 mm, 3.0 μm) column using methanol-1.0 mmol ammonium acetate solution in 80:20 (v/v) ratio. The protonated precursor to product ion transitions studied for CXB and CXB-D7 were m/z 380.0 → 315.9 and 387.0 → 323.0, respectively.
Results: The limit of detection (LOD) and lower limit of quantitation of the method were 2.50 and 10.0 ng/ml respectively with a linear dynamic range of 10.0-4000 ng/ml for CXB. The intra-batch and inter-batch precision (% CV) and mean relative recovery across quality control levels is<7.2 % and 85.5 % respectively. Matrix effect in human plasma, expressed as IS-normalized matrix factor ranged from 0.99-1.03.
Conclusion: The method was successfully applied in healthy subjects using a single dose of 400 mg celecoxib capsules under fasting and fed conditions. The reproducibility in the measurement of study data is demonstrated by incurred sample reanalysis.
Downloads
References
Frampton JE, Keating GM. Celecoxib: a review of its use in the management of arthritis and acute pain. Drugs 2007;67:2433-72.
Davies NM, McLachlan AJ, Day RO, Williams KM. Clinical pharmacokinetics and pharmacodynamics of celecoxib: a selective cyclo-oxygenase-2 inhibitor. Clin Pharmacokinet 2000;38:225-42.
Chow HHS, Anavy N, Salazar D, Frank DH, Alberts DS. Determination of celecoxib in human plasma using solid-phase extraction and high-performance liquid chromatography. J Pharm Biomed Anal 2004;34:167-74.
Jalalizadeh H, Amini M, Ziaee V, Safa A, Farsam H, Shafiee A. Determination of celecoxib in human plasma by high-performance liquid chromatography. J Pharm Biomed Anal 2004;35:665-70.
Emami J, Fallah R, Ajami A. A rapid and sensitive HPLC method for the analysis of celecoxib in human plasma: application to the pharmacokinetic studies. DARU 2008;16:211-7.
Zarghi A, Shafaati A, Foroutan SM, Khoddam A. Simple and rapid high-performance liquid chromatographic method for determination of celecoxib in plasma using UV detection: application in pharmacokinetic studies. J Chromatogr B 2006;835:100-4.
Zhang M, Moore GA, Gardiner SJ, Begg EJ. Determination of celecoxib in human plasma and breast milk by high-performance liquid chromatographic assay. J Chromatogr B 2006;830:245-8.
Abdel-Hamid M, Novotny L, Hamza H. Liquid chromatographic-mass spectrometric determination of celecoxib in plasma using single-ion monitoring and its use in clinical pharmacokinetics. J Chromatogr B 2001;753:401-8.
Gika HG, Theodoridou A, Michopoulos F, Theodoridis G, Diza E, Settas L, et al. Determination of two COX-2 inhibitors in serum and synovial fluid of patients with inflammatory arthritis by ultra performance liquid chromatography-inductively coupled plasma mass spectroscopy and quadrupole time-of-flight mass spectrometry. J Pharm Biomed Anal 2009;49:579-86.
Brautigam L, Vetter G, Tegeder I, Heinkele G, Geisslinger G. Determination of celecoxib in human plasma and rat microdialysis samples by liquid chromatography tandem mass spectrometry. J Chromatogr B 2001;761:203-12.
Werner U, Werner D, Pahl A, Mundkowski R, Gillich M, Brune K. Investigation of the pharmacokinetics of celecoxib by liquid chromatography-mass spectrometry. Biomed Chromatogr 2002;16:56-60.
Park MS, Shim WS, Yim SV, Lee KT. Development of simple and rapid LC–MS/MS method for determination of celecoxib in human plasma and its application to bioequivalence study. J Chromatogr B 2012;902:137-41.
Guidance for Industry, Bioanalytical Method Validation, US Department of Health and Human Services, Food and Drug Administration Centre for Drug Evaluation and Research (CDER), Centre for Veterinary Medicine (CVM); 2001.
Patel DS, Sharma N, Patel MC, Patel BN, Shrivastav PS, Sanyal M. Development and validation of a selective and sensitive LC–MS/MS method for determination of cycloserine in human plasma: application to bioequivalence study. J Chromatogr B 2011;879:2265-73.
Logoyda L. Bioanalytical method development and validation for the simultaneous determination of verapamil and enalapril in the present of enalaprilat by HPLC-MS/MS. Int J Appl Pharm 2018;10:9-27.
Guidance for Industry: ICH E6 Good Clinical Practice, U. S. Department of Health and Human Services, Food and Drug Administration, Centre for Drug Evaluation and Research (CDER), Centre for Biologics Evaluation and Research (CBER); 1996.
Yadav M, Shrivastav PS. Incurred sample reanalysis: a decisive tool in bioanalytical research. Bioanalysis 2011;3:1007-24.
Tijare LK, Rangari NT, Mahajan UN. A review on bioanalytical method development and validation. Asian J Pharm Clin Res 2016;9 Suppl 3:6-10.