DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF ETHINYL ESTRADIOL AND GESTODENE IN BULK AND PHARMACEUTICAL DOSAGE FORMS
DOI:
https://doi.org/10.22159/ijpps.2021v13i7.41615Keywords:
RP-HPLC, Method development, Method validation, Forced degradation studiesAbstract
Objective: The principal objective of this study is to develop and validate a simple, new, fast, selective, precise, and economic stability-indicating the RP-HPLC method for the simultaneous estimation of Ethinyl estradiol and Gestodene in a bulk and pharmaceutical dosage form.
Methods: The present method was developed and validated on a Waters HPLC system using Phenomenex Gemini C18(250 mm × 4.6 mm i.d., 5 µm particle size) column and mobile phase composition of phosphate buffer: Acetonitrile (75:25 v/v) and the pH was adjusted to 3.6 using dilute orthophosphoric acid. The system was regulated at 1.0 ml/min flow rate at 237 nm UV detection.
Results: The two drugs Ethinyl Estradiol and Gestodene, were eluted at 1.788 min and 3.475 min retention time, respectively. The analytical parameters such as accuracy, precision, linearity, LOD, LOQ, ruggedness, and robustness were used for validating the developed method according to International Conference on Harmonisation [ICH] guidelines. Linearity was exhibited over the concentration range of 10-50µg/ml and 25-125µg/ml for Ethinyl Estradiol and Gestodene, respectively. The method revealed the Limit of Detection and Quantitation values for Ethinyl Estradiol and Gestodene were 1.399µg/ml, 3.909µg/ml and 4.24µg/ml, 11.85µg/ml, respectively. The stress testing was carried out to give rise to degradation products by exposing the drugs to acid, alkali, thermal, oxidative, photolytic, and hydrolytic degradation. The obtained data showed that the content of Active pharmaceutical ingredients and the degradation products were successfully separated without any interference, which confirmed the stability-indicating nature of the developed method.
Conclusion: The new, simple, rapid, selective, precise, and economic stability-indicating RP-HPLC method has been successfully developed and validated. It can be satisfactorily applied for the periodic laboratory quantitative estimation of Ethinyl Estradiol and Gestodene in formulations and active pharmaceutical ingredients.
Downloads
References
https://en.m.wikipedia.org/wiki/Ethinylestradiol [Last accessed on 10 Feb 2021]
https://pubchem.ncbi.nlm.nih.gov/compound/Ethinylestradiol [Last accessed on 10 Feb 2021]
https://en.m.wikipedia.org/wiki/Gestodene [Last accessed on 10 Feb 2021].
https://pubchem.ncbi.nlm.nih.gov/compound/Gestodene [Last accessed on 10 Feb 2021]
Kanchan Nautiyal, Ramakrishna K. Analytical method development and validation for simultaneous determination and quantification of ethinyl estradiol and gestodene in combined tablet dosage form by RP-HPLC. J Chem Pharm Sci 2014;6:74-80.
Aleksandra Laban, Slavko Markovic, Milena Stankov, Predrag Djurdjevic. Simultaneous determination of gestodene and ethinyl estradiol in contraceptive formulations by RP-HPLC. Anal Lett 2004;37:273-82.
Xiong Z, Sun X, Huo T, Li N, Zheng Y, Sun Y. Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma. Biomed Chromatogr 2010;24:160-8.
Kishore Kumar I, Jayaprakash P, Sivannarayana Reddy V, Sriramulu J. A stability-indicating high-performance liquid chromatographic method for separation and quantification of impurities in ethinylestradiol and gestodene tablets. J Pharm Biol 2017;7:33-40.
Praveen C, Ranganath MK, Divakar P. Method development and validation for simultaneous estimation of ethinyl estradiol and drospirenone and forced degradation behavior by HPLC in the combined dosage form. Pharm Anal Acta 2013;4:1-5.
ICH, Q2B-Validation of Analytical procedures; Methodology, International Conference on Harmonization; 1996.
International Conference on Harmonization, ICH Q1 A [R2]; Stability Testing of New Drug substances and products; 2003.
Snyder LR, Kirkland JJ, Glajch JL. Practical HPLC method development. 2nd ed. Hoboken: John Wiley and Sons, Inc; 1997.
Vikas Kumar Pal, Yogendra Pal. Analytical method development and method validation for determination assay and content uniformity of levonorgestrel by reversed-phase high-performance liquid chromatography. Asian J Pharm Clin Res 2020;13:101-7.
Majan Naim, Aejaz Ahmed, Khan GJ. Stability indicating reverse-phase High-Performance liquid chromatography method development and validation for simultaneous estimation of Telmisartan and Benidipine hydrochloride in the pharmaceutical dosage form. Asian J Pharm Clin Res 2018;11:342-50.