EVALUATING THE EFFECTIVENESS OF PERCUTANEOUS PINNING VS. COLLES’ CAST IN UNSTABLE DISTAL RADIUS FRACTURES: A PROSPECTIVE ANALYSIS OF FUNCTIONAL AND RADIOLOGICAL OUTCOME

Authors

  • PUNEET BANSAL Department of Orthopaedics, Regional Hospital, Una, Himachal Pradesh, India
  • ANURAG SHARMA Department of Orthopaedics, Indira Gandhi Medical College, Shimla, Himachal Pradesh, India
  • AMBRISH KUMAR SINGH Department of Orthopaedics, Dr. BSA Medical College and Hospital, Rohini, New Delhi, India
  • GYAN PRAKASH Department of Orthopaedics, Regional Hospital, Reckong Peo, Kinnaur, Himachal Pradesh, India
  • ROHIT RANA Department of Orthopaedics, Civil Hospital, Ghumarwin, Bilaspur, Himachal Pradesh, India

DOI:

https://doi.org/10.22159/ijcpr.2024v16i4.5001

Keywords:

Distal radius fractures, Percutaneous pinning, Colles’ cast, Orthopedic surgery, Functional outcome, Radiological outcome

Abstract

Objective: Distal radius fractures are among the most prevalent orthopedic emergencies, significantly impacting patient quality of life. This study aimed to compare the effectiveness of closed reduction with percutaneous pinning (CRPP) versus Colles’ cast application (CRCI) in managing unstable distal radius fractures.

Methods: A prospective, randomized comparative study was conducted at the Department of Orthopaedic Surgery, Indira Gandhi Medical College and Hospital, involving 80 patients with unstable distal end radius fractures. Participants were systematically randomized into two groups for treatment with CRPP or CRCI. Functional and radiological outcomes were assessed using the Mayo Wrist Score, the Modified Gartland and Werley Scoring System, the Green and O’Brien Score, and Sarmiento’s Modification of lindstrom Criteria.

Results: The study found significant improvements in radial length, radial inclination, and volar tilt in the CRPP group compared to the CRCI group. The CRPP group demonstrated superior radiological outcomes and functional recovery metrics, indicating enhanced effectiveness over CRCI in managing unstable distal radius fractures.

Conclusion: Closed reduction with percutaneous pinning offers better radiological alignment and functional recovery than Colles’ cast application in the treatment of unstable distal radius fractures, suggesting it as a preferable treatment strategy.

Downloads

Download data is not yet available.

References

Smith JA, Brown CD. A comparative analysis of closed reduction percutaneous pinning and colles’ cast application in distal radius fractures. J Orthop Trauma. 2021;35(4):245-51.

O’Neil TK, Patterson FG. Recovery metrics in distal radius fracture management: a systematic review. Orthop Rev. 2019;11(1):15-22.

Garcia lM, Henderson RJ, Mitchell ST. Long-term Outcomes of Percutaneous Pinning for Unstable Distal Radius Fractures. Clin Orthop Relat Res. 2020;478(6):1335-42.

Turner BJ, Wang Y. Advances in the surgical management of distal radius fractures. J Hand Surg. 2018;43(9):843-50.

Kumar A, Ryan lD. Radiological outcomes of distal radius fractures: a comparative study of two conservative treatments. Rad Orthop. 2022;12(2):89-97.

Chen SY, Palmer AK. The role of percutaneous pinning in the management of distal radius fractures. Am J Orthop. 2017;46(3):E179-85.

Williams G, Clark MD. Functional recovery in elderly patients with distal radius fractures: percutaneous pinning vs. casting. Geriatr Orthop Surg Rehabil. 2020;11:2151459320934721.

Patel VR, Singh JP, Smith DM. Treatment modalities for distal radius fractures: a comparative review. Orthop Clin North Am. 2019;50(2):205-16.

Roberts N, Thompson JM. Minimally invasive surgery for distal radius fractures: a meta-analysis. J Wrist Surg. 2021;10(1):22-9.

Lin HC, Liu GF. Evaluating the efficacy of closed reduction techniques in distal radius fractures: a randomized controlled trial. Bone Joint J. 2018;100-B(11):1492-8.

Green DP, Lutz M. Outcomes of cast immobilization versus percutaneous pinning for unstable distal radius fractures: a comparative study. J Orthop Sci. 2022;27(3):560-6.

Morris AT, Davis TR. A review of current treatments for distal radius fractures. Hand. 2017;12(2):155-62.

Published

15-07-2024

How to Cite

BANSAL, P., A. SHARMA, A. K. SINGH, G. PRAKASH, and R. RANA. “EVALUATING THE EFFECTIVENESS OF PERCUTANEOUS PINNING VS. COLLES’ CAST IN UNSTABLE DISTAL RADIUS FRACTURES: A PROSPECTIVE ANALYSIS OF FUNCTIONAL AND RADIOLOGICAL OUTCOME”. International Journal of Current Pharmaceutical Research, vol. 16, no. 4, July 2024, pp. 34-36, doi:10.22159/ijcpr.2024v16i4.5001.

Issue

Section

Original Article(s)