Abstract

Objective: The objective of this research was to estimate the concentrations of N-Acetyl-L-cysteine (NAC) and Ambroxol Hydrochloride (AMB) simultaneously, in bulk and combined tablet formulation using a new, simple, precise and accurate absorption correction method using UV Spectrophotometer.

Methods: The concentrations of both the drugs (NAC and AMB) were determined using absorption correction method as; at 244 nm only AMB gave substantial absorbance and at 220 nm both NAC and AMB gave absorbance. Distilled water was used as a common solvent for both the drugs and the method was developed. Further statistical evaluations were carried out and the method was validated.

Results: In the range of 3-18 µg/ml for AMB at 244 nm and 20-120 µg/ml for NAC at 220 nm, the Beer's law was obeyed. Percentage recovery for AMB was in the range 100.50-101.10% and for NAC it was 99.85-100.20%. The % RSD values reported were less than 2. The developed method was validated and was found to be linear, accurate, precise and also rugged.

Conclusion: The results obtained clearly demonstrated that the proposed method of analysis was simple, sensitive, accurate, precise, rapid and also economical and could be applied successfully for the simultaneous estimation of NAC and AMB in bulk and combined tablet formulation.

Keywords: N-Acetyl-L-cysteine, Ambroxol Hydrochloride, Absorption correction method, Mucolytic, UV spectrophotometer

Downloads

Download data is not yet available.

References

Parfitt K, editor. Martindale: The Complete Drug Reference. 32nd ed. London: The Pharmaceutical Press; 1999. p. 1052.

Vander Heyden Y, Mangelings D, Van Brempt J, Spapen H. Development and validation of an HPLC method with post-column derivatisation to assay n-acetylcysteine in plasma. Acta Chromatographica 2004;14:149-164.

Holdiness MR. Clinical pharmacokinetics of N-acetylcysteine. Clin Pharmacokinet 1991;20(2):123-344.

Murty B, Kapoor J, Kim M. Estimation of acetylcysteine and its preparations. Am J Hosp Pharm 1977; 34(3):305-6.

Raggi M, Caurini V, Pietra A. High-pressure liquid chromatographic (HPLC) analysis of imidazole antifungals in commercial dosage forms. J Pharm Sci 1982;71(12):1384-86.

Kolar M, Dobcnik D. Chemically prepared silver electrode for determination of N-acetyl-L-cysteine by flow-injection potentiometry. Pharmazie 2003;58(1):25-8.

Vinas P, Lopez Garcia I, Martinez GJA. FIA titrations of sulphide, cysteine and thiol containing drugs with chemiluminescent detection. J Pharm Biomed Anal 1993;11(1):15-20.

Willian T, Heberth J, Orlando F. Flow injection turbidimetric determination of acetylcysteine in pharmaceutical formulations using silver nitrate as precipitant reagent. J Braz Chem Soc 2007;18(5):1028-33.

Drozdz R, Naskalski J, Zabek-Adamska A. Dynamics of reactive oxygen species generation in the presence of copper(II)–histidine complex and cysteine. Acta Biochimica Polonica 2007;54(1):205-11.

Cardoso de Sa A, Paim L, Bicalho U, Carmo DR. Determination of N-acetylcysteine by cyclic voltammetry using modified carbon paste electrode with copper nitroprusside adsorbed on the 3-aminopropylsilica. Int J Electrochem Sci 2011;6(9):3754-67.

Carmo D, Silva R, Straditto N. Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode. J Braz Chem Soc 2003;14(4):616-20.

Baeyens W, Weken G, Ling B, De Moerloose P. Hplc Determination of N-Acetylcysteine in Pharmaceutical Preparations After Pre-Column Derivatization With Thiolyte MB Using Fluorescence Detection. Analytical Letters 1988;21(5):741-57.

Celma C, Allue J, Prunonosa J, Peraire C, Obach R. High-performance liquid chromatographic determination of N-acetylcysteine in human serum following acetaminophen overdosage. J Chrom A 2000;870(1,2):13-22.

Toussaint B, Pitti C, Streel B, Ceccato A, Hubert P, Crommen J. Quantitative analysis of N-acetylcysteine and its pharmacopeial impurities in a pharmaceutical formulation by liquid chromatography-UV detection-mass spectrometer. J Chrom A 2000;896(1,2):191-99.

Lewis P, Woodward A, Maddock J. Improved method for the determination of N-acetylcysteine in human plasma by high-performance liquid chromatography. J Chrom A 1985;327:261-67.

Holdiness R, Morgan Jr L, Gillen E, Harrison F. High-performance liquid chromatographic determination of N-acetylcysteine in human serum following acetaminophen overdosage. Journal of Chromatography B: Biomedical Sciences and Applications 1986;382:99-106.

Orlovic D, Radulovic D, Vujic Z. Determination of S-Carboxymethyl-L-Cysteine, Methylparaben and their Degradation Products in Syrup Preparations. Chromatographia 2004;60(5,6):329-33.

Hannestad U, Sorbo B. Determination of 3-mercaptolactate, mercaptoacetate and N-acetylcysteine in urine by gas chromatography. Clin Chim Acta 1979;95(2):189-200.

The Extra Pharmacopoeia. 34th ed. London: Pharmaceutical Press; 2004. p. 1114.

Pospisilova M, Polasek M, Jokl V. Determination of ambroxol or bromhexine in pharmaceuticals by capillary isotachophoresis. J Pharm Biomed Anal 1997;24:421–8.

The Merck Index. 13th ed. Merck & Co. Inc.: New Jersey, 2001.

Gillissen A, Nowak D. Characterization of N-acetylcysteine and ambroxol in antioxidant therapy. Respir Med 1998;92:609-623.

Maarit H, Coral B. Validation of an HPLC Method for The Quantification of Ambroxol Hydrochloride and Benzoic Acid in A Syrup as Pharmaceutical Form Stress Test for Stability Evaluation. J Pharm Biomed Anal 2001;24:1005–10.

Botterbolm MHA. Rapid and Sensitive Determination of Ambroxol in Human Plasma and Urine by High-Performance Liquid Chromatography. J Chrom B 1987;421:211–5.

Flores-Murrieta FJ, Hoyo-Vadillo C, Hong E, Castaneda-Hernandez G. Assay of Ambroxol in Human Plasma by High-Performance Liquid Chromatography with Amperometric Detection. J Chrom B 1989;490:464–9.

Koundrourellis JE, Eleftheria TM, Theodora AB. High Performance Liquid Chromatographic Determination of Ambroxol in the Presence of Different Preservatives in Pharmaceutical Formulations. J Pharm Biomed Anal 2000;23:469–75.

Colombo L, Marcucci F, Marini MG, Pierfederici P, Mussini E. Determination of Ambroxol in Biological Material by Gas Chromatography with Electron Capture Detection. J Chrom B 1990;530:141–7.

Schmid J. Assay of Ambroxol in Biological Fluids by Capillary Gas-Liquid Chromatography. J Chrom B 1987;414:65–75.

Hohyun K, Jeong-Yeon Y, Sang BH, Hee JL, Kyung RL. Determination of Ambroxol in Human Plasma by LC-MS/MS. J Pharm Biomed Anal 2003;32:209–16.

Pospisilova M, Polasek M, Jokl V. Determination of Ambroxol and Bromhexine in Pharmaceuticals by Capillary Isotachophoresis. J Pharm Biomed Anal 2001;24:421–8.

Published

01-05-2016

How to Cite

Kinjawadekar, V., S. Boddu, D. Jadhav, and S. Rathod. “ABSORPTION CORRECTION METHOD FOR THE SIMULTANEOUS ESTIMATION OF N-ACETYL-L-CYSTEINE AND AMBROXOL HYDROCHLORIDE IN BULK AND IN COMBINED TABLET DOSAGE FORM”. International Journal of Pharmacy and Pharmaceutical Sciences, vol. 8, no. 5, May 2016, pp. 191-5, https://journals.innovareacademics.in/index.php/ijpps/article/view/11242.

Issue

Section

Original Article(s)