DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINING METFORMIN HYDROCHLORIDE IN DRIED BLOOD SPOTS

Authors

  • Yahdiana Harahap Bioavailability and Bioequivalence Laboratory, Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.
  • Prastiwi Arum Sari Bioavailability and Bioequivalence Laboratory, Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.
  • Catur Jatmika Bioavailability and Bioequivalence Laboratory, Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.

DOI:

https://doi.org/10.22159/ijap.2018.v10s1.26

Keywords:

Metformin, High-performance liquid chromatography, Optimization, Validation, Dried blood spot

Abstract

Objective: This study aimed to develop an analytical method for determining metformin concentrations in human dried blood spots (DBS) using
optimal chromatographic conditions and DBS preparation methods and validate the analytical methods.
Methods: Analysis metformin HCl performed using C-18 columns (250 mm × 4.6 mm) at a column temperature of 40°C with a mobile phase acetonitrile
phosphate buffer (40:60% v/v) at pH 7.0 using a flow rate of 0.8 mL/min, a photodiode array detector at a wavelength of 234 nm, and atorvastatin
calcium as an internal standard. Samples were prepared by protein precipitation with 60% methanol and then drying using nitrogen gas at 60°C for
15 min before reconstituting in 200 μL of the mobile phase.
Results: Invalidation procedures, the present methods met the acceptance criteria stated in the EMEA Bioanalytical Guideline 2011. The method was
also linear at the concentration range of 25.0–5000.0 ng/mL (r=0.9997).
Conclusion: The developed method for determination of metformin HCl in DBS sample was valid with a concentration range of 25.0–5000.0 ng/mL
and can be applied to in vivo studies.

Downloads

Download data is not yet available.

References

WHO. Global Report on Diabetes. Geneva: WHO Press; 2016.

Aburuz S, Millership J, McElnay J. Dried blood spot liquid

chromatography assay for therapeutic drug monitoring of metformin.

J Chromatogr B Analyt Technol Biomed Life Sci 2006;832:202-7.

Lakshmy R. Analysis of the use of dried blood spot measurements in

disease screening. J Diabetes Sci Technol 2008;2:242-3.

Brem H, Tomic-Canic M. Cellular and molecular basis of wound

healing in diabetes. J Clin Invest 2007;117:1219-22.

Michigan State University. Department of Chemistry. Internal Standard;

Available from: https://www.2.chemistry.msu.edu/courses/

cem434/Swain_2015_Excel_Problems/Internal%20Standard%20%20

Standard%20Addition%20.pdf. [Last cited on 2016 Oct 08].

EMEA. Guideline on Bioanalytical Method Validation. London:

Committee for Medicinal Products for Human Use (CHMP); 2011.

David V, Medvedovici A, Albu F. Retention behavior of metformin

and related impurities in ion-pairing liquid chromatography. J Liq

Chromatogr Relat Technol 2005;28:81-95.

Elshaboury SR, Mohamed NA, Ahmed S, Farrag S. An efficient ionpair

liquid chromatographic method for the determination of some H2

receptor antagonists. J Chromatogr Sci 2016;54:419-28.

Majidano SA, Khuhawar MY. GC determination of famotidine,

ranitidine, cimetidine, and metformin in pharmaceutical preparation and

serum using methylglyoxal as derivatizing reagent. Chromatographia

;75:1311-7.

Kolte BL, Raut BB, Deo AA, Bagool MA, Shinde DB. Simultaneous

determination of metformin in its multicomponent dosage forms with

glipizide and gliclazide using micellar liquid chromatography. J Liq

Chromatogr Relat Technol 2003;26:1117-33.

Iwasaki Y, Sawada T, Hatayama K, Ohyagi A, Tsukuda Y, Namekawa K,

et al. Separation technique for the determination of highly polar

metabolites in biological samples. Metabolites 2012;2:496-515.